Features
SLASH YOUR HOT WATER BILL
Because our hot water heat pump uses energy from the air, it uses much less electrical energy to heat your water, which can shave off up to 80%* from your cost to heat you water.
*depending on your hot water usage

Specifications
HE-UM60AR | |
---|---|
Heat output at 19.0°C ambient / 14.0°C cold water inlet* | 5.0kW |
Electric input at 19.0°C ambient / 14.0°C cold water inlet* | 0.96kW |
COP at 19.0°C ambient / 14.0°C cold water inlet* | 5.2 |
Power input (Max) | 2.3kW |
Current input (Max) | 10A |
Circuit breaker size | 15A |
Standby power consumption | 5.05W |
Power supply | 230V/Hz – 240V/Hz Vac (power input is voltage x amps x power factor) / 50Hz (single phase) |
Heat pump refrigerant | CO₂ (R744) |
Heat pump hot water delivery temperature | 63°C – 67°C Variable (based on heat pump inlet temperature |
Range of operating ambient temperature | -10°C to 43°C |
Heat pump unit weight | 46kg |
Heat pump location | Outdoor |
Noise level | 37dB |
Dimensions (H x W x D) | 672mm x 799mm x 299mm |
Rain resistance | IPX4 |
Water port connections (Inlet / Outlet) | 1/2″ BSP, 12.7mm |
Built-in freeze and frost control | Variable. Depends on the relative humidity, water, & ambient temperature (i.e. about 5°C water temperature & 5°C ambient temperature). |
Note | *As per AS/NZ Standard 5125 |